Wuxi Owgels Medical Instruments Co., Ltd

Wuxi Owgels Medical Instruments Co., Ltd

Manufacturer from China
Active Member
5 Years
Home / Products / Covid-19 Antigen Rapid Test Kit /

Fresh Swabs Rapid Diagnostic Test Kit OEM 95.52% Sensitivity 25T/kit

Contact Now
Wuxi Owgels Medical Instruments Co., Ltd
City:wuxi
Province/State:jiangsu
Country/Region:china
Contact Person:Soohia
Contact Now

Fresh Swabs Rapid Diagnostic Test Kit OEM 95.52% Sensitivity 25T/kit

Ask Latest Price
Certification :CE; ISO
Place of Origin :Beijing
MOQ :10-100pcs
Price :USD1.8-3.5/pc
Supply Ability :1million per week
Delivery Time :3-5working days
Packaging Details :25pcs per case
clinical specificity :100%
Overall Agreement :96.21%
Certificate :CE
Sensitivity :95.52%
clinical sensitivity is 91.08% :91.08%
Material :Plastic
Origin :China
Dimension :17*12.7*7cm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Nasal/Throast SwabTest Kits Antigen Test for fresh swabs COVID-19 Antigen Rapid Diagnostic

Interference

Potential Endogenous Interference of the COVID-19 Antigen Rapid Test was evaluated using natural clinical samples. No Antigen false negative or false positive results were observed with the following potential interference substances at the stated concentrations:

Human Blood 1% V/V
Mucosal protein 1mg/ml
Phenylephrine 1% V/V
Oxymetazoline 1% V/V
Triamcinolone 50mg/L
Ribavirin 50mg/L

Overall Clinical Performance of Antigen Test Kit

A total of above 157 positive samples and 260 negative samples were detected to evaluate the clinical performance of the COVID-19 Antigen Rapid Test Kit. The Result is below:

Sansure Covid-19 RT-PCR Assay
Positive Negative Total
Kewei COVID-19 Antigen Rapid Assay Positive 143 0 143
Negative 14 260 274
Total 157 260 417

INTERPRETATION OF RESULTS

NEGATIVE:

If only the C band is present, the absence of any burgundy color in the T band indicates that no COVID-19 antigens are detected in the specimen. The result is negative.

POSITIVE:

In addition to the presence of C band, if T band also emerged, then the test indicates the presence of COVID-19 antigens in the specimen. The result is positive.

INVALID:

Control line fails to appear. Incorrect procedural techniques and invalid test kit are the most likely reasons for control line failure. Read the instructions carefully again and repeat the test with a new test kit. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

Fresh Swabs Rapid Diagnostic Test Kit OEM 95.52% Sensitivity 25T/kit

Fresh Swabs Rapid Diagnostic Test Kit OEM 95.52% Sensitivity 25T/kit

Fresh Swabs Rapid Diagnostic Test Kit OEM 95.52% Sensitivity 25T/kit

Fresh Swabs Rapid Diagnostic Test Kit OEM 95.52% Sensitivity 25T/kit

Fresh Swabs Rapid Diagnostic Test Kit OEM 95.52% Sensitivity 25T/kit